RANGER 8 + DIESEL
OPERATOR’S MANUAL
IM612
April, 1998
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
R
RANGER 8+ DIESEL
For use with machines having Code Numbers:
10533
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
World's Leader in Welding and Cutting Products Premier Manufacturer of Industrial Motors
RETURN TO MAIN MENU
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - RANGER 8 + DIESEL

RANGER 8 + DIESEL™OPERATOR’S MANUALIM612April, 1998Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety

Strany 2 - MAGNETIC FIELDS

RANGER 8+ DIESELA-2INSTALLATION A-2INSTALLATION INSTRUCTIONSSAFETY PRECAUTIONSOnly qualified personnel should install,use, or service this equipmen

Strany 3 - FUMES AND GASES

RANGER 8+ DIESELA-3INSTALLATION A-3LIFTINGThe RANGER 8+ DIESEL weighs approximately695 lbs/315 kg. A lift bail is mounted to the machineframe and s

Strany 4

RANGER 8+ DIESELA-4INSTALLATION A-4FUELFill the fuel tank with clean No. 2, diesel fuel only. Donot fill to the top of the filler neck to allow roo

Strany 5 - REDRESSEUR

RANGER 8+ DIESELA-5INSTALLATION A-5ELECTRICAL CONNECTIONSSee Figure B.1 in the OPERATION section of thismanual for the location of the 115 and 230 v

Strany 6 - Thank You

RANGER 8+ DIESELA-6INSTALLATION A-6AUXILIARY POWER RECEPTACLES,PLUGS, AND HAND-HELD EQUIPMENTThe control panel of the RANGER 8+ DIESEL fea-tures thr

Strany 7 - TABLE OF CONTENTS

RANGER 8+ DIESELA-7INSTALLATION A-7Connection of RANGER 8+ DIESEL to premiseswiring must be done by a licensed electrician andmust comply with the N

Strany 8

B-1OPERATIONRANGER 8+ DIESELB-1GENERAL DESCRIPTIONThe RANGER 8+ DIESEL is a diesel-engine driven,multi-process AC and DC arc welder and AC powergenera

Strany 9

B-2OPERATIONB-2DIESEL ENGINERuggerini - RD 201 features:• Air cooled, twin cylinder.• Direct injection.• Crankcase in diecast aluminium.• Forced lubri

Strany 10 - INSTALLATION

B-3OPERATIONB-3CONTROLS AND SETTINGSAll generator/welder controls are located on theOutput Control Panel of the machine case front.Diesel engine idler

Strany 11

B-4OPERATIONB-410. WELD OUTPUT TERMINAL (TO ELECTRODEHOLDER) WITH FLANGE NUT: Provides the con-nection point for the electrode holder cable.11. WELD

Strany 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Strany 13

B-5OPERATIONB-5RANGER 8+ DIESELENGINE OPERATIONDO NOT RUN THE ENGINE AT EXCESSIVESPEEDS. The maximum allowable high idle speedfor the RANGER 8+ DIESE

Strany 14

B-6OPERATIONB-6RANGER 8+ DIESELBREAK-IN PERIODAny engine will use a small amount of oil during its“break-in” period. For the diesel engine on theRANG

Strany 15

B-7OPERATIONB-7RANGER 8+ DIESELWELDING PROCESSSTICK (CONSTANT CURRENT) WELDINGConnect welding cables to the "TO WORK” and"ELECTRODE” studs.

Strany 16 - OPERATION

B-8OPERATIONB-8RANGER 8+ DIESELSummary of Welding ProcessesCONTROL ELECTRODECABLE IDLE WHEN NOT

Strany 17

B-9OPERATIONB-9RANGER 8+ DIESELAUXILIARY POWERThe RANGER 8+ DIESEL can provide up to 9,000watts of 115/230 volts AC, Single phase 60 HZ powerfor conti

Strany 18

B-10OPERATIONB-10RANGER 8+ DIESEL115/230 VOLT DUAL VOLTAGE RECEPTACLEThe 115/230 volt receptacle can supply up to 40 ampsof 230 volt power to a two wi

Strany 19

C-1ACCESSORIESC-1GENERAL OPTIONS / ACCESSORIESThe following options/accessories are available foryour RANGER 8+ DIESEL from your local LincolnDistribu

Strany 20

C-2ACCESSORIESC-2SEMIAUTOMATIC FCAW AND MIGWELDING OPTIONS / ACCES-SORIESK449 LN-25 - Includes internal contactor for acrossthe arc operation (no cont

Strany 21

RANGER 8+ DIESELACCESSORIES - CONNECTION DIAGRAMSC-3C-3CONNECTION OF RANGER 8+ DIESEL TO LN-7 & K240 CONTACTOR KITWARNING: Turn the power off when

Strany 22

D-1MAINTENANCED-1ROUTINE MAINTENANCE1. At the end of each day’s use, refill the fuel tank tominimize moisture condensation in the tank.Running out of

Strany 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Strany 24

D-2MAINTENANCED-2ENGINE ADJUSTMENTSOVERSPEED IS HAZARDOUSThe maximum allowable high idle speed for thismachine is 3750 RPM, no load. Do NOT tamperwit

Strany 25

RANGER 8+ DIESELE-1TROUBLESHOOTINGE-1If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, co

Strany 26 - ACCESSORIES

E-2TROUBLESHOOTINGE-2RANGER 8+ DIESELObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test pro

Strany 27

E-3TROUBLESHOOTINGE-3RANGER 8+ DIESELObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test pro

Strany 28 - RANGER 8+ DIESEL

E-4TROUBLESHOOTINGE-4RANGER 8+ DIESELObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test pro

Strany 29 - MAINTENANCE

F-1DIAGRAMSF-1RANGER 8+ DIESELWIRING DIAGRAM - RANGER 8+ DIESELM1910712-11-97NOTE: This diagram is for reference only. It m

Strany 30

F-2DIAGRAMSF-2RANGER 8+ DIESELM1910812-11-97MAXIMUM OVERALL DIMENSIONS:LENGT

Strany 32

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Strany 33

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Strany 34

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Strany 35 - DIAGRAMS

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Strany 36

PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissent dan

Strany 37 - NOTES

Thank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much p

Strany 38 - Mas t er C ardMasterCard

viTABLE OF CONTENTSPageInstallation...

Strany 39

viiTABLE OF CONTENTSPageMaintenance .......Section DSafet

Strany 40

A-1INSTALLATION RANGER 8+ DIESELA-1TECHNICAL SPECIFICATIONS - RANGER 8+ DIESEL (K1632-1)Make/Model Description Speed (RPM) Displacement Starting Cap