Magnum PCT125/PCT125M
OPERATOR’S MANUAL
IM543
July, 2004
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
... and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before you
act and be careful.
3
3
4
C
E
I
I
E
C
6
0
9
7
4
-
7
A
-
1
4
1
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © 2004 Lincoln Global Inc.
RETURN TO MAIN MENU
Zobrazit stránku 0
1 2 3 4 5 6 ... 24 25

Shrnutí obsahu

Strany 1 - Magnum PCT125/PCT125M

Magnum PCT125/PCT125MOPERATOR’S MANUALIM543July, 2004Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safet

Strany 2

A-3INSTALLATION PLASMA TORCHA-33. Unscrew the wing nut and remove the pilot leadof the torch cable from the pilot stud.4. Loosen the strain relief c

Strany 3 - Apr. ‘93

B-1OPERATIONB-1OPERATIONRefer to your Pro-Cut operator’s manual for completeoperating information.When plasma cutting, it is necessary to wearproper e

Strany 4

C-1MAINTENANCEC-1MAINTENANCEELECTRIC SHOCK CAN KILL• Only qualified personnel should per-form this installation.• Turn the input power OFF at the dis-

Strany 5 - PRÉCAUTIONS DE SÛRETÉ POUR

C-2MAINTENANCEC-2REPLACEMENT INSTRUCTIONSFOR PCT125M CABLE AND TORCHHEAD ASSEMBLYELECTRIC SHOCK can kill.• Turn the input power off to the Pro-Cut usi

Strany 6 - Thank You

C-3MAINTENANCEC-39. Untape and remove the insulation.10. Separate the torch head from the cable using two5/8" open end wrenches.11. Replace the t

Strany 7 - TABLE OF CONTENTS

C-4MAINTENANCEC-415. Slide the insulating tube over the cable and torchhead connections to the back of the torch headand align the holes in the insula

Strany 8

PLASMA TORCHD-1TROUBLESHOOTINGD-1If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contac

Strany 9

D-2TROUBLESHOOTINGD-2PLASMA TORCHObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedu

Strany 10 - INSTALLATION

D-3TROUBLESHOOTINGD-3PLASMA TORCHObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedu

Strany 11 - OPERATION

D-4TROUBLESHOOTINGD-4PLASMA TORCHObserve all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedu

Strany 12 - MAINTENANCE

iSAFETYiPROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDRENAWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFOR

Strany 13

NOTESPLASMA TORCH

Strany 14

NOTESPLASMA TORCH

Strany 15

NOTESPLASMA TORCH

Strany 16 - TROUBLESHOOTING

PLASMA TORCHWARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTUR

Strany 17

PLASMA TORCHWARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO

Strany 18

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Strany 19

iiSAFETYiiFOR ELECTRICALLYpowered equipment.6.a. Turn off input power using the disconnectswitch at the fuse box before working on theequipment.6.b. I

Strany 21

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Strany 22

PLASMA TORCHvvThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company produc

Strany 23

PLASMA TORCH TABLE OF CONTENTSPageSPECIFICATION SUMMARY...

Strany 24

A-1INSTALLATION PLASMA TORCHA-1SPECIFICATIONS SUMMARYK880-1 PCT125 Hand-held Plasma Torch with 25 ft. (7.6m) cable K880-2 PCT125 Hand-held Plasma To

Strany 25

A-2INSTALLATION PLASMA TORCHA-2GENERAL DESCRIPTIONThe Magnum PCT125/PCT125M plasma torches havebeen designed for use on a Pro-Cut 125. All of theto