Zobrazit stránku 0
Ranger 250
OPERATOR’S MANUAL
IM833-C
June, 2005
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
For use with machines having Code Numbers:
11117, 11118, 11167, 11168, 11270, 11271
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © 2005 Lincoln Global Inc.
RETURN TO MAIN MENU
Zobrazit stránku 0
1 2 3 4 5 6 ... 48 49

Shrnutí obsahu

Strany 1 - Ranger 250

Ranger 250OPERATOR’S MANUALIM833-CJune, 2005Safety Depends on YouLincoln arc welding and cuttingequipment is designed and builtwith safety in mind. H

Strany 2 - MAGNETIC FIELDS

A-2INSTALLATION RANGER 250A-2MACHINE SPECIFICATIONS - Ranger 250 (K1725-6, K1725-7, K1725-8, K1725-9)RECEPTACLES AUXILIARY POWER CIR

Strany 3 - ARC RAYS can burn

A-3INSTALLATION RANGER 250A-3LIFTINGThe RANGER 250 weighs approximately 575 lbs. witha full tank of gasoline. A lift bail is mounted to themachine a

Strany 4

A-4INSTALLATION RANGER 250A-44. Typical conditions of use, i.e., travel speed; rough-ness of surface on which the trailer will be operat-ed; environ

Strany 5 - REDRESSEUR

A-5INSTALLATION RANGER 250A-5An incorrect spark arrester may lead to damage tothe engine or adversely affect performance.---------------------------

Strany 6 - Thank You

A-6INSTALLATION RANGER 250A-6Table A.1 lists recommended cable sizes and lengthsfor rated current and duty cycle. Length refers to thedistance from

Strany 7 - TABLE OF CONTENTS

A-7INSTALLATION RANGER 250A-7240 Volt60 Hz.3-WireServicePOWERCOMPANYMETER240 VOLT120 VOLT120 VOLTLOADNNEUTRALBUSGROUNDPREMISESDISCONNECT ANDSERVICEO

Strany 8

A-8INSTALLATION RANGER 250A-8CONNECTION OF LINCOLN ELEC-TRIC WIRE FEEDERSConnection of LN-7 or LN-8 to the Ranger 2501. Shut the welder off.2. Conn

Strany 9

A-9INSTALLATIONA-97. Set the "IDLE" switch to the "AUTO" position.When not welding, the Ranger 250 engine will beat the low idle s

Strany 10 - INSTALLATION

B-1OPERATIONRANGER 250B-1GENERAL DESCRIPTIONThe Ranger 250 is a gasoline engine powered DCmulti-process welding power source and 120 / 240volt AC powe

Strany 11

B-2OPERATIONB-2WELDING CONTROLS:1. OUTPUT CONTROL: The CONTROL dialprovides continuous control of the welding current orwelding voltage depending on t

Strany 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Strany 13

B-3OPERATIONB-34. WELD OUTPUT TERMINALS WITHFLANGE NUT:Provides a connection point for the electrode andwork cables. Output stud covers provided on co

Strany 14

B-4OPERATIONB-4Operating the starter motor for more than 5 secondscan damage the motor. If the engine fails to start,release the switch and wait 10 se

Strany 15

B-5OPERATIONB-5TIG WELDINGThe TOUCH START TIG setting of the MODE switch is forDC TIG (Tungsten Inert Gas) welding. To initiate a weld,the CONTROL dia

Strany 16

B-6OPERATIONB-6ARC GOUGINGThe Ranger 250 can be used for limited arc gouging.For optimal performance, set the MODE switch to CC-STICK and the ARC CONT

Strany 17

C-1ACCESSORIESC-1RECOMMENDED OPTIONALEQUIPMENTK957-1 HEAVY DUTY, TWO WHEEL TRAILER FORSMALL WELDERS - For road, off-road and in-plantand yard towing.

Strany 18 - OPERATION

D-1MAINTENANCED-1RANGER 250KOHLER ENGINE (1) Service more frequently when used in dusty areas and/or at high ambienttemperatures.SAFETY PRECAUTIONS• H

Strany 19

D-2MAINTENANCED-2ENGINE OIL CHANGEDrain the oil while the engine is warm to assure rapidand complete draining.• Remove the oil filler cap and dipstick

Strany 20

D-3MAINTENANCED-3AIR FILTER PAPER ELEMENT1. Loosen the cover retaining knob and remove thecover.2. Remove the pre-cleaner from the paper element.3. Re

Strany 21

D-4MAINTENANCED-4FUEL FILTER1. Check the fuel filter for water accumulation or sedi-ment.2. Replace the fuel filter if it is found with excessivewater

Strany 22

D-5MAINTENANCED-5RANGER 250WELDER / GENERATORMAINTENANCESTORAGE: Store the RANGER 250 in clean, dry pro-tected areas.CLEANING: Blow out the generator

Strany 23

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Strany 24 - ACCESSORIES

E-1TROUBLESHOOTINGE-1RANGER 250If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact

Strany 25 - MAINTENANCE

E-2TROUBLESHOOTINGE-2RANGER 250Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedure

Strany 26

E-3TROUBLESHOOTINGE-3RANGER 250Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedure

Strany 27

E-4TROUBLESHOOTINGE-4RANGER 250Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedure

Strany 28

E-5TROUBLESHOOTINGE-5RANGER 250Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test procedure

Strany 29

F-1DIAGRAMSF-1RANGER 250 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this

Strany 30 - TROUBLESHOOTING

F-2DIAGRAMSF-2RANGER 250

Strany 31

F-3DIAGRAMSF-3RANGER 250

Strany 32

F-4DIAGRAMSF-4RANGER 250

Strany 33

F-5DIAGRAMSF-5RANGER 250

Strany 34

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Strany 35 - DIAGRAMS

F-6DIAGRAMSF-6RANGER 250

Strany 36 -

F-7DIAGRAMSF-7RANGER 250or service this equipment.Only qualified personnel should install,useKeep away from moving parts.Keep guards in place.MOVING P

Strany 37

F-8DIAGRAMSF-8RANGER 250

Strany 38

F-9DIAGRAMSF-9RANGER 250

Strany 39

F-10DIAGRAMSF-10RANGER 250 29/03

Strany 40

F-11DIAGRAMSF-11RANGER 250

Strany 41

CCIRCUITBREAKERS41.201046.517.50444.519.50495.3TRUCK/UNDERCARRIAGE MOUNTING HOLES7.22183.324.86631.32.6266.523.50596.915.50393.7CENTER OF GRAVITY29.8

Strany 42

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Strany 43

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Strany 44

• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Strany 45

ivSAFETYivMar. ‘93PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques q

Strany 46 - DIMENSION PRINT

vvThank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as much

Strany 47

viviTABLE OF CONTENTSPageInstallation...

Strany 48

viiviiTABLE OF CONTENTSMaintenance.......Section DSafet

Strany 49

Make/Model Description Horsepower Operating Displacementcu. in.(cu. cm)Starting Capacities@ 3600 RPM SPEED Bore x Stroke in.(mm)SystemRANGER