WELDMARK 225
OPERATOR’S MANUAL
For Machines with Code Number 10946
IM766
April, 2002
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
R
• Manufactured by Lincoln Electric Company •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
Date of Purchase:
Serial Number:
Code Number:
Model:
Where Purchased:
Copyright © 2002 Lincoln Global Inc.
RETURN TO MAIN MENU
Zobrazit stránku 0
1 2 3 4 5 6 ... 35 36

Shrnutí obsahu

Strany 1 - WELDMARK 225

WELDMARK 225OPERATOR’S MANUALFor Machines with Code Number 10946IM766April, 2002Safety Depends on YouLincoln arc welding and cuttingequipment is desi

Strany 2 - MAGNETIC FIELDS

A-3INSTALLATION WELDMARK 225A-3INSTALLATION INSTRUCTIONSSafety PrecautionsMachine GroundingBecause this portable engine driven welder or genera-to

Strany 3 - FUMES AND GASES

A-4INSTALLATION WELDMARK 225A-4Some of the factors to be considered are as follows:1. Design capacity of trailer vs. weight of equipmentand likely

Strany 4

• Damage to the fuel tank may causefire or explosion. Do notdrill holesin the WELDMARK 225 base or weldto the WELDMARK 225 base.A-5INSTALLATION W

Strany 5 - REDRESSEUR

A-6INSTALLATION WELDMARK 225A-6Connection of the LN-7 to the Weldmark 225• Shut the welder off.• Connect the LN-7 and the K240 contactor kit perins

Strany 6 - Thank You

Load From WEM 2239-1115V/230VDual Voltage Each Half of Total FromReceptacle Each 115V Both 115VDuplex Duplexes0 20* 701.1 KW 20* 603.4 KW 20* 405.7

Strany 7 - TABLE OF CONTENTS

A-8INSTALLATION WELDMARK 225A-8TABLE lllELECTRICAL DEVICE USE WITH THE WELDMARK 225Type Common Electrical Devices Possible ConcernsResistive Heater

Strany 8

A-9INSTALLATION WELDMARK 225A-9Standby Power ConnectionsThe Weldmark 225 is suitable for temporary, standby,or emergency power using the engine man

Strany 9

A-10INSTALLATION WELDMARK 225A-10Connection of Weldmark 225 to premises wiringmust be done by a licensed electrician and mustcomply with the Nation

Strany 10 - INSTALLATION

B-1OPERATIONWELDMARK 225B-1GENERAL DESCRIPTIONThe Weldmark 225 is a twin-cylinder, gasoline driven,multiprocess arc welder and AC power generator. It

Strany 11

B-2OPERATIONB-2Welder Controls - Function and OperationENGINE “ON-OFF” SwitchWhen placed in the “ON” position, this switchenergizes the engine ignitio

Strany 12

FOR ENGINEpowered equipment.1.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be running.

Strany 13

B-3OPERATIONB-3Starting/Shutdown InstructionsStarting the EngineBe sure all Pre-Operation Maintenance has been per-formed. Also, read the Engine Owne

Strany 14

B-4OPERATIONB-4Welding ProcessStick (Constant Current) WeldingConnect welding cables to the "TO WORK” and"ELECTRODE” studs. Start the engin

Strany 15

B-5OPERATIONB-5WELDMARK 225Summary of Welding ProcessesCONTROL ELECTRODECABLE IDLE WHEN NOT

Strany 16

C-1ACCESSORIESC-1WELDMARK 225OPTIONAL EQUIPMENT (Field Installed)K957-1 HEAVY DUTY, TWO WHEEL TRAILER FORSMALL WELDERS - For road, off-road and in-p

Strany 17

C-2ACCESSORIESC-2WELDMARK 225RECOMMENDED EQUIPMENTSTICKK704 Accessory Kit which includes:• Electrode Holder & Cable• Work Clamp & Cable• H

Strany 18 - OPERATION

D-1MAINTENANCED-1WELDMARK 225SAFETY PRECAUTIONSHave qualified personnel do the maintenancework. Turn the engine off before working insidethe machine.

Strany 19

D-2MAINTENANCED-2Engine AdjustmentsOVERSPEED IS HAZARDOUSThe maximum allowable high idle speed for thismachine is 3750 RPM, no load. Do NOT tamperwit

Strany 20

E-1TROUBLESHOOTINGE-1WELDMARK 225If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, conta

Strany 21

E-2TROUBLESHOOTINGE-2WELDMARK 225Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test proced

Strany 22

E-3TROUBLESHOOTINGE-3WELDMARK 225Observe all Safety Guidelines detailed throughout this manualIf for any reason you do not understand the test proced

Strany 23 - ACCESSORIES

iiSAFETYiiARC RAYS can burn.4.a. Use a shield with the proper filter and coverplates to protect your eyes from sparks andthe rays of the arc when weld

Strany 24

WELDMARK 225F-1DIAGRAMSF-1NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific

Strany 25 - MAINTENANCE

F-2DIAGRAMSF-2WELDMARK 225CONNECTION OF WELDMARK 225 TO LN-7 & K240 CONTACTOR KITWARNING: Turn the power off when making connections.N.A. Use pow

Strany 26

F-3DIAGRAMSF-3WELDMARK 225LOF SHAFT9.2921.219.312.7517.0026.5919.1130.289.099.09UNDERCARRIAGE MOUNTING HOLES42.25CENTER OF GRAVITY WITH OIL INENGINE

Strany 27 - TROUBLESHOOTING

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Strany 28

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S INSTRUC

Strany 29

WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE

Strany 30 - DIAGRAMS

•Manufactured by Livcoln Electric Company •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.

Strany 31

FOR ELECTRICALLYpowered equipment.8.a. Turn off input power using the disconnectswitch at the fuse box before working onthe equipment.8.b. Install equ

Strany 32

ivSAFETYivPRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parra

Strany 33 - Lincoln Welding School

Thank Youfor selecting a QUALITY product We want you to take pridein operating this product ••• as much pride as we have inbringing this product to yo

Strany 34

viTABLE OF CONTENTSPageInstallation...

Strany 35

A-1INSTALLATION WELDMARK 225A-1* Based on a 10 min. period.TECHNICAL SPECIFICATIONS - WELDMARK 225 WEM 2239-1 INPUT - GASOLINE ENGINERATED OUTP

Strany 36

A-2INSTALLATION WELDMARK 225A-2AC STICK / TIG (CC) OUTPUTA 225 OUTPUT RANGEB 50 OUTPUT RANGEABOUTPUT AMPSOUTPUT VOLTS AC (RMS)050 100 150 20025