INVERTEC V300-PRO
OPERATOR’S MANUAL
For use with machines Code 10256 and 10257.
IM526-B
December,1999
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
ful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT. And, most
importantly, think before you act
and be careful.
Date of Purchase:
Serial Number:
Code Number:
Model:
Where Purchased:
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
RETURN TO MAIN MENU
Zobrazit stránku 0
1 2 3 4 5 6 ... 39 40

Shrnutí obsahu

Strany 1 - INVERTEC V300-PRO

INVERTEC V300-PROOPERATOR’S MANUALFor use with machines Code 10256 and 10257.IM526-BDecember,1999Safety Depends on YouLincoln arc welding and cuttin

Strany 2 - ARC WELDING can be hazardous

LN-9 GMA Connection Instructions 1. Turn the Invertec power switch “off”.2. Connect the K596 control cable assembly from theLN-9 GMA to the Invertec c

Strany 3 - Mar. ‘93

– 11 –OPERATING INSTRUCTIONSDUTY CYCLEThe Invertec is rated at 300 amps, 60% duty cycle for3 phase inputs (based on a 10 minute cycle). It is alsorate

Strany 4 - REDRESSEUR

–CV FCAW This setting has been optimized forInnershield®and Outershield®flux-coredelectrodes.CV GMAW Short circuit, glob and spray transfersolid wire

Strany 5 - TABLE OF CONTENTS

– 13 –Meter Polarity SwitchThe wire feeder polarity switch is located at the rear ofthe machine. The switch provides a work connectionfor wire feeder

Strany 6 - Thank You

– 14 –PERIODIC MAINTENANCEOverload ProtectionThe machine is electrically protected from producinghigh output currents. Should the output currentexceed

Strany 7 - INSTALLATION

– 15 –TROUBLESHOOTING GUIDETrouble What To DoNot output but fan operates and meter is on.Poor welding, weld settings drift, or output power islow.Main

Strany 8 - OF AN ENGINE WELDER

–– 16 –TEST PROCEDURESStep1A1B23A3BNextTestStep1B23A3B4and5TestOutput pilot circuit(set S4 on)Protection PCboard output (setS4 on)Static capacitorbala

Strany 9 - – 9 –– 9 –

– 17 –Step4NextTestStepcont5cont5cont5cont5cont5cont5cont5cont5cont5cont5cont5cont5TestSwitch PC Boardresistance test.No dynamic testis possible.Remov

Strany 10 - 60% 300 1/0 2/0

– 18 –Step56NextTestStepcontcontcontcontTestSnubberResistorsDisconnect leads401, 402, 403 and404 from SwitchPC BoardOutput diodesRemove outputloadRepa

Strany 11

Repair ActionReplace D13, inspect S1,test C1 and C2Replace D13, inspect S1,test C1 and C2Replace D13, inspect S1,test C1 and C2Replace D13, inspect S1

Strany 12 - TERMINALS

– 2 –PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDRENAWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE O

Strany 13 - EXPLODING PARTS can cause

–Matched PartsCertain parts must be replaced in matched sets.Matched sets are required in the following areas:Output diodes: D1, D2, D3, D4 and D5Outp

Strany 14

– 21 –Replacement of Power Modules and OutputDiodesInput rectifier, D13, is a power module. When mount-ing power modules, the heat sink and module mou

Strany 15 - TROUBLESHOOTING GUIDE

– 22 –TURN THE POWER SWITCH OF THE WELDING POWERSOURCE "OFF" BEFORE INSTALLING PLUGS ON CABLESOR WHEN CONNECTING OR DISCONNECTING PLUGS TOWE

Strany 16 - TEST PROCEDURES

– 23 –INSTALLATION INSTRUCTIONSTHIS CONNECTOR IS MEANT TO BE USED WITH LINCOLN POWER SOURCES WHICH HAVE A 14-PINTO ANY OF THE 14 CIRCUITS PRESENT IN T

Strany 17

– 24 –N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN PO

Strany 18

– 25 –N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN PO

Strany 19

– 26 –N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.N.B. DIAGRAM SHOWS ELECTRODE POSITIVE. TO CHANGE POLARITY, TURN PO

Strany 20

– 27 –Only qualified persons should install, use orservice this machine.using the disconnect switch at the fuse boxWARNINGTurn off input power to the

Strany 21

– 28 –Only qualified persons should install, use orservice this machine.using the disconnect switch at the fuse boxWARNINGTurn off input power to the

Strany 22 - WELDING POWER SOURCE

– 29 –TOWORK+POWER SOURCEINVERTECDC TIG STARTER-WARNINGELECTRICSHOCKCAN KILLOnly qualified persons should install, use or service this machine.Turn of

Strany 23 - INSTALLATION INSTRUCTIONS

– 3 –FOR ENGINEpowered equipment.7.a. Turn the engine off before troubleshooting and maintenancework unless the maintenance work requires it to be run

Strany 24 - 12-10-93A

– 30 –Only qualified persons should install, use orservice this machine.using the disconnect switch at the fuse boxWARNINGTurn off input power to the

Strany 25 - 1-25-91

– 31 –N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.TOWORK-+14 PINAMPHENOLSPARE8281424131322421GND75767731322421GNDN.C.K867 UNIVERSALADAPTER PLUGN.D.N.

Strany 26 - 12-10-93A

– 32 –CONTROLCONTROL PANELARC FORCE/INDUCTANCE22WR11227/INDUCTANCE CONTROL TERMINALCHOKE10K2152274303301CW (MAX)METERTOP S2C5L3R8D2SHUNT1211A381B

Strany 27 - S19899

– 33 –212RECTIFIER9DC2R79A9AN.F.CONTROL PANELJ11, J14SF9H5402, 404ONOFFH1RVCH612BBOTTOM51WIRING DIAGRAM V300-PRO CODE 10257 (575V)SHUNTR8250L3L1C1TP2

Strany 28 - 4-19-96D

INVERTEC V300-PRO & V300-INOTES

Strany 29 - CAN KILL

INVERTEC V300-PRO & V300-INOTES

Strany 30

INVERTEC V300-PRO & V300-INOTES

Strany 31 - 9-11-92

Now Available...12th EditionThe Procedure Handbook of Arc WeldingWith over 500,000 copies of previous editions publishedsince 1933, the Procedure Hand

Strany 32 - ELECTRICAL SYMBOLS PER E1537

– 38 –WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicREAD AND UNDERSTAND THE MANUFACTURER’S I

Strany 33

– 39 –WARNINGAVISO DEPRECAUCIONATTENTIONWARNUNGATENÇÃOSpanishFrenchGermanPortugueseJapaneseChineseKoreanArabicLEIA E COMPREENDA AS INSTRUÇÕES DO FABRI

Strany 34

– 4 –PRÉCAUTIONS DE SÛRETÉPour votre propre protection lire et observer toutes les instructionset les précautions de sûreté specifiques qui parraissen

Strany 35

–• Sales and Service through Subsidiaries and Distributors Worldwide •Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB

Strany 36

– 5 –TABLE OF CONTENTSPageSafety Precautions ...

Strany 37 - Lincoln Welding School

– 6 –Thank Youfor selecting a QUALITY product by Lincoln Electric. We want youto take pride in operating this Lincoln Electric Company product••• as m

Strany 38

PRODUCT DESCRIPTIONThe Invertec V300-PRO is a 300 amp arc weldingpower source that utilizes single or three phase inputpower to produce either constan

Strany 39

–– 8 –INPUT VOLTAGE SETUPPOWER CORD CONNECTIONA 10 ft. (3.0m) power cord is provided and wired intothe machine. Follow the power cord connectioninstr

Strany 40

– 9 –– 9 –remote control adapter and K857 remote controlare required for remote output control).5. Set the meter polarity switch on the rear of theInv